4.5 The Drive and Programming Modes
The drive functions are divided into two main groups accessible via the digital LED operator:
Drive Mode:
The Drive mode allows motor operation and parameter monitoring. Most parameter settings cannot be changed
when accessing functions in the Drive Mode.
Programming Mode:
The Programming Mode allows access to setup/adjust, verify parameters and Auto-Tuning. The drive
prohibits changes in motor operation such as start/stop when the Digital LED Operator is accessing a function in the
Programming Mode.
u
Changing Parameter Settings or Values
This example explains changing C1-01, Acceleration Time 1, from 10.0 seconds to 20.0 seconds.
Step
Display/Result
1.
Turn on the power to the drive. The initial display appears.
2.
Press the
key until the Setup Mode Screen appears.
3.
Press the
key to view the parameter setting display.
4.
Scroll through parameters by pressing the
key until C1-01 appears.
5.
Press
to view the current setting value (10.0). (Number farthest to the left flashes)
6.
Press
until the desired number is selected. (“1” flashes)
7.
Press the
key and enter 0020.0.
8.
Press
and the drive will confirm the change.
9.
The display automatically returns to the screen shown in Step 4.
10.
Press the
key until back at the initial display.
4.5 The Drive and Programming Modes
YASKAWA
TOEP YAIQPM 03B YASKAWA AC Drive - iQpump Micro User Manual
73
4
Start-Up Programming & Operation
Содержание iQpump Micro CIMR-PW Series
Страница 443: ......