7-9
Power unit
POWR
13. Remove the fuse box, and then
disconnect the fuse box couplers
u
,
v
,
and connector
w
.
14. Disconnect the oil pressure sensor
coupler
x
, thermoswitch connectors
y
,
and ignition coil couplers
A
, and then
remove the bracket
e
.
15. Disconnect the starter relay leads
B
,
PTT relay coupler
D
and ground leads
E
.
16. Remove the air temperature sensor
coupler
F
and YDIS coupler
G
.
Installing the wiring harness
To install all of the wiring harnesses, see
“Wiring harness routing” (5-6).
1.
Install the sensors and switches that
were removed to the power unit.
2.
Install the air temperature sensor coupler
a
and YDIS coupler
b
.
3.
Connect the starter relay leads
c
, PTT
relay couplers
d
, and ground leads
e
.
u
v
w
x
y
A
e
E
B
D
F
G
a
b
e
c
d
Содержание F150B
Страница 1: ...SERVICE MANUAL 6BM 28197 5L 11 F150B FL150B ...
Страница 4: ......
Страница 12: ...0 7 GEN INFO General information Symbol Name Application LOCTITE 242 blue Sealant LOCTITE 572 white Sealant ...
Страница 211: ...6 34 Vapor separator 0 1 2 3 4 5 6 7 8 9 10 A MEMO ...
Страница 311: ...8 32 Shimming regular rotation model 0 1 2 3 4 5 6 7 8 9 10 A Shim location F R P T3 T1 T2 ...
Страница 351: ...8 72 Shimming counter rotation model 0 1 2 3 4 5 6 7 8 9 10 A Shim location F R P T3 T2 T4 T1 ...
Страница 448: ...A 1 MEMO ...
Страница 451: ......
Страница 452: ...Printed in China Jul 2008 0 6 1 ABE E_4 YAMAHA MOTOR CO LTD ...
Страница 458: ......