2-10
Electronic control system
0
1
2
3
4
5
6
7
8
9
10
A
Ignition timing control system
F150B uses ignition timing control system to control the ignition timing and the duration of ignition
coil energization. High output power, improved fuel economy, and low exhaust emissions are
attained by properly controlling the ignition timing and the duration of ignition coil energization in
response to every engine operating conditions, based on the signals from each sensor and the map
data.
Basic ignition timing
computation
Optimal ignition timing is selected from the map data in accordance with
the signals from each sensor.
Computation for com-
pensation
Ignition timing is advanced or retarded in response to the engine operat-
ing conditions determined by the signals from each sensor.
Stable idle
speed
As the idle speed drops, ignition timing is advanced to
make it stable. Ignition timing is retarded as the idle speed
gets higher.
Start-up
operation
Engine startability is improved by applying the advanced
ignition timing at the engine start-up. Subsequently, the
ignition timing is controlled to go back to the standard angle
gradually.
compensati
on for
acceleration
Ignition timing is temporarily retarded at acceleration to
improve the throttle response.
Shift-cutout
When the conditions are met for implementing the shift cut-
out control, the specified angle is added to the ignition tim-
ing at every updating cycle until it reaches the shift-cutout
compensation angle. Otherwise, the specified angle is sub-
tracted from the ignition timing at every updating cycle until
it reaches 0°CA.
Ignition timing
restriction
Engine
temperature
restriction
Optimal ignition timing is selected from the map data
depending on the cooling water temperature detected by
the engine temperature sensor.
Ignition
timing upper
and lower
limits
restriction
Limit values for advancing and retarding the ignition timing
are computed by the map data in accordance with the
engine speed detected by the pulser coil.
Computing the
duration of
energization
The duration of ignition coil energization is controlled based on the engine
speed and the supply voltage to the ignition coil.
Содержание F150B
Страница 1: ...SERVICE MANUAL 6BM 28197 5L 11 F150B FL150B ...
Страница 4: ......
Страница 12: ...0 7 GEN INFO General information Symbol Name Application LOCTITE 242 blue Sealant LOCTITE 572 white Sealant ...
Страница 211: ...6 34 Vapor separator 0 1 2 3 4 5 6 7 8 9 10 A MEMO ...
Страница 311: ...8 32 Shimming regular rotation model 0 1 2 3 4 5 6 7 8 9 10 A Shim location F R P T3 T1 T2 ...
Страница 351: ...8 72 Shimming counter rotation model 0 1 2 3 4 5 6 7 8 9 10 A Shim location F R P T3 T2 T4 T1 ...
Страница 448: ...A 1 MEMO ...
Страница 451: ......
Страница 452: ...Printed in China Jul 2008 0 6 1 ABE E_4 YAMAHA MOTOR CO LTD ...
Страница 458: ......