6H95G11
9-8
9
8
7
6
5
4
3
2
1
Electrical
Starting system (continued from previous page)
Disassemble and check the
starter motor.
Yes
Check the starter relay for
continuity.
No
Replace the starter relay.
Is there continuity?
Symptom: The battery loses power quickly. (W)
9
Be sure the electrolyte level and gravity are specific condition.
9
Be sure the wireharness, couplers and connectores are good connection.
Charging system
Check the lighting coil output
peak voltage.
Check the rectifier output peak
voltage.
Replace the battery, and then
check the all of the electrical
equipment on the boat.
Replace the lighting coil.
Replace the rectifier.
No
Does the out-
put peak voltage
exceed specifi-
cation values?
Yes
No
Does the out-
put peak voltage
exceed specifi-
cation values?
Yes
6H95G11_09 04.7.5 11:53 Page 9
Содержание EK40G
Страница 1: ...EK40J SERVICE MANUAL 6H9 28197 5G 11 EK40G ...
Страница 4: ......
Страница 16: ...GEN INFO 1 11 6H95G11 MEMO ...
Страница 28: ...2 11 6H95G11 SPEC MEMO ...
Страница 54: ...FUEL 4 13 6H95G11 Fuel system 6H94030E No Part name Q ty Remarks 18 Check valve 2 19 Screw 4 ø5 24 mm ...
Страница 103: ...6H95G11 6 4 9 8 7 6 5 4 3 2 1 Special service tools Backlash indicator 90890 06706 ...
Страница 122: ...LOWR 6 23 6H95G11 Lower unit Shimming M T 6F660860 ...
Страница 145: ...6H95G11 6 46 9 8 7 6 5 4 3 2 1 Drive shaft and lower case Shimming Shimming T3 M3 M2 6F660440 T2 T1 M1 ƒ π ...
Страница 152: ...BRKT 7 1 6H95G11 Bracket unit Special service tools Needle bearing attachment 90890 06613 Driver rod L3 90890 06652 ...
Страница 199: ......