Delayed Egress
Installation Instructions
7100, 7200 Series Exit Device
80-9470-0162-000 10/20
Diagonistic LEDs
Function
Yellow
ON - LBM Bypass DIP switch position 7 is OFF-set ON
OFF- LBM Bypass DIP switch position is ON (normal operation)
Red (Push Rail Switch)
ON- Rail Push Bar is depressed.
OFF- Rail Push Bar is released.
Orange (Door Status Switch)
ON- Door Status Switch is open. Door is open/violated.
OFF- Door Status Switch is closed or DPS Bypass DIP switch position 6 is ON.
Green (Solenoid)
ON- Rail Solenoid is energized. (+24 VDC from main board)
OFF- Rail Solenoid is de-energized.
Refer to the following table and notes for an explanation of each LED’s function.
NOTE: If device is not working properly after troubleshooting, contact your local hardware distributor
or local Yale representative, or contact Yale.
Problem
Solution
Power is applied, but
unit will not arm (No red
LED).
• Check all connections on circuit board and wire harness.
• Check for power 24VDC at power inputs (-black) and (+red) and
check polarity.
• Check wire transfer for any bad connections or broken wires.
• Check power output at power supply.
• Must be 24VDC regulated.
Device alarms contin-
uously when power is
applied.
• Check trigger mechanism wire harness on circuit board and all other
connections.
• Check pushpad activating switch in device.
Units with Door Position
Switch (made by other
manufacturers).
• Make sure DPS is wired (electrically closed - with door closed) into
wire harness. Make sure DPS is working properly by using a meter to
check continuity when door is opened and closed.
Device allows mechanical
latchbolt retraction with
power applied and LED
shows armed.
• Check for correct power, 24VDC regulated.
• Check for correct amperage on power supply (must be rated equal or
greater than device, 500mA minimum).
Exit device latchbolt/rods
will not latch properly.
• Refer to standard exit device installation instructions troubleshooting
guide.
24