Copyright ©2018, 2020 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in
part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited
For technical support contact Yale
®
at 800.438.1951 x5033 or [email protected]
25
Delayed Egress
7100, 7200 Series Exit Device
Installation Instructions
80-9470-0162-000 10/20
Upon depressing the pushpad for 1 second or longer, the device will sound an audible beeping tone
and allow the door to be opened within 15 (or 30) seconds. The tone will then change to a continuous
alarm until reset. Resetting of the alarm and re-arming of the device occurs automatically once the
door has been returned to the closed position for 30 seconds. The 30-second re-arming timer will
re-start if the pushpad is depressed or the door is re-opened before actual re-arming of the device
occures. A DPS (Door Position Switch) is required for the BOCA option.
NOTE: BOCA option is not suitable for installations in accordance with NFPA 101.
22
BOCA 15 Second Delay and BOCA 30 Second Delay
23
NFPA 101 Requirements: 30 Second Delay
Upon depressing the pushpad for 3 seconds or longer, the device will sound an audible beeping tone
and allow the door to be opened after 30 seconds. The tone will then change to a continuous alarm
until reset. Resetting of the alarm and re-arming of the device is accomplished by manual means only.
Note: If an external DPS is not used, Standard trim and Safe/Secure trim will allow entry without
affecting the device in an armed mode. The device will only be affected when the push pad is
depressed. Latchbolt monitor switch is a SPDT switch that monitors security of latchbolt or vertical
rods.
Latchbolt Monitor Switch
S Suffix
Latchbolt monitor switch is a SPDT switch that monitors security of latchbolt or vertical rods.
21
Additional Options Non ElectroLynx Wiring, continued