Copyright ©2018, 2020 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in
part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited
For technical support contact Yale
®
at 800.438.1951 x5033 or [email protected]
5
Delayed Egress
7100, 7200 Series Exit Device
Installation Instructions
80-9470-0162-000 10/20
2
End Cover and PC Board Assembly
Rear Cover End Cap
1-1/8" (29)
Mortise Cylinder
with Yale 2160 Cam
®
(Order Separately)
1765 Series
Cylinder Collar
(Order separately
when required)
End Cover
Circuit Board Assembly
Indicator Light (
)
LED
Lens Cover
Arming Switch Activator
Tabs
NOTE: Factory keyed orders will
be shipped assembled.
Cylinder Nut
Activator Legs
1765 Series
Cylinder Collar
1-1/8"
(29)
1-1/2"
(38)
2160 Cam
Dia
.742"
(18.9
mm)
Order Separately
®
NOTE: • Use Yale
®
2153 x 2160 cam,
1-1/8" mortise cylinder
• For cylinders over 1-1/8",
use Yale
®
1765 Series cylinder ring.
Typical Mortise Cylinder
1. Trim device to proper length as required.
36" Exit Device - 1" maximum can be trimmed
48" Exit Device - 6" maximum can be trimmed
2. Carefully slide circuit board assembly into end Cover to ensure indicator light (LED) is not bent.
3. Insert mortise cylinder into end cover with keyway horizontal, as shown.
4. Slide arming switch activator over mortise cylinder so activator legs are on each side of switch.
5. Insert flange of cylinder nut into arming switch activator to allow rotation of activator.
6. Tighten cylinder nut on mortise cylinder and to secure circuit board assembly.
7.
Verify assembly by rotating key counter clockwise and clockwise. Key should move freely and
arming switch should trip for both rotation directions. If key does not rotate freely, verify cylinder
nut was placed in correct orientation. If arming switch does not trip, activator legs on arming
switch activator can be bent to reduce or increase rotational travel.
Figure 2