Delayed Egress
7100, 7200 Series Exit Device
Installation Instructions
80-9470-0162-000 10/20
4
Installation of End Cover Assembly to Device
1. Turn end cover assembly over to circuit board side.
2. Ensure eight S2 Dip Switches are set for application (see previous page).
3. Slide end cover assembly into device, making sure not to pinch or crimp wires.
4. Connect device lock assembly harness to connector J1. Place wire connectors and excess wire
between end cover and P.C. board. (Figure 3, Device End View)
5. Check all connections before proceeding.
6. Proceed to device mounting (see packed instructions).
Connector J2
To Power Transfer Hinge
Optional "O", "S" or
Safe/Secure wire
(Refer to wiring diagram
for wiring)
Place Connector
and Excess Wire
in this Area
J1 Connector
Plugs into Device Lock Assembly
4
5
NOTE: Review J5 Alarm Relay NO or NC selection above. If NC contact is required, remove PBCA/
cover assembly from rail, move 2-pin jumper to NC, then re-install PCBA/cover on rail.
Device End View
Figure 3