VX-3R O
PERATING
M
ANUAL
42
M
EMORY
S
TORAGE
1. Select the desired frequency while operating in the VFO mode. Be sure to set up any
desired CTCSS or DCS tones, as well as any desired repeater offset. The power level
may also be set at this time, if you wish to store it.
2. Press and hold in the [
F/W
] key for 1/2 seconds.
3. Within five seconds of releasing the [
F/W
] key, you need to make a decision regarding
channel storage. The microprocessor will automatically select the next-available “free”
channel (a memory register on which no data has been stored). If you do not wish to
make a change and accept the “free” channel, proceed to step 4. If you wish to select a
different channel number into which to store the data, rotate the
DIAL
knob to select
the desired memory channel.
Note
: Do not forget to pull the
DIAL
knob to rotate the
DIAL
knob.
Advice
: You may jump 100 memory channels, if you’re in a hurry (101
Æ
201
Æ
301 …),
by pressing the [
TXPO
] key (multiple times, if necessary). Any channel that you see
with a blinking channel number currently has no data written on it (i.e. the channel is
“free”).
4. Press the [
F/W
] key once more to store the frequency into memory.
5. You will still be operating in the “VFO” mode, so you may now enter other frequen-
cies, and store them into additional memory locations, by repeating the above process.
1) You may change the automatic memory channel selection feature to select
the “next-highest memory channel above the
last-stored
memory channel”
instead of the “next-available ‘free’ channel” via the Set Mode Item 50: MW
WMD; see page 114.
2) You may disable the memory write function which prevents a memory write operation
if you should accidentally perform a wrong key sequence via the Set Mode Item 53:
MRPTCT. See page 114 for details. When the memory write protect is activated, the
“PROTCT” notation appears on the display while a memory write operation is being
performed.
I
MPORTANT
N
OTE
On rare occasions the memorized data may become corrupted by miss operation, or
static electricity. When repairs are made the memory data may be lost. Please write
down or record the memorized information so you will be able to restore it if needed.
M
EMORY
M
ODE
(
R
EGULAR
M
EMORY
C
HANNEL
O
PERATION
)
Содержание VX-3R
Страница 29: ...VX 3R OPERATING MANUAL 27 REPEATER OPERATION NOTE...