VX-3R O
PERATING
M
ANUAL
122
Set Mode Item 82
[
STEP
]
Function
: Setting the Dial frequency steps.
Available Values
: AUTO/5/8.33/9/10/12.5/15/20/25/50/100 kHz
Default
: AUTO (Step automatically changes according to operating frequency.)
Note
: 1) This Set Mode Item can select and set the Dial frequency steps to individual
memory channels when Memory Offset Tuning is enabled as shown on page 46.
2) 9 kHz steps are available only when receiving on the BC band.
3) 8.33 kHz steps are available only when receiving on the Air band.
4) While operating on the BC band, you may only select channel steps of 9 kHz or 10 kHz;
the other step selections are disabled.
5) 5 kHz steps are not available for use on 250 - 300 MHz, nor above 580 MHz.
Set Mode Item 83
[
STEREO
]
Function
: Enables/Disables the stereo output, while receiving the FM Broadcast band.
Available Values
: STEREO/MONO
Default
: STEREO
Note
: This Set Mode Item can select and set the function to each memory channel indi-
vidually.
Set Mode Item 84
[
SUB-RX
]
Function
: Sets the time before Broadcast audio is resumed after the amateur band signal
drops, when the AF Priority function is activated.
Available Values
: OFF/TRX 1S - TRX 10S (1S/step)/HOLD/ TX 1S - TX 10S (1S/step)
Default
: OFF
TRX 1S - TRX 10S: Broadcast audio is resumed 1 to 10 seconds after the received signal
drops or your Transmission ends
HOLD:
Broadcast audio is not resumed after the receive signal drops or your
transmission ends.
TX 1S - TX 10S:
Broadcast audio is resumed 1 to 10 seconds after your Transmission
ends. Audio is resumed immediately when the received signal drops.
Set Mode Item 85
[
TEMP
]
Function
: Indicates the current temperature inside the transceiver’s case and selects the
measurement units (“°F” or “°C”) for the temperature sensor.
Press the [
MODE
] key to toggle the measurement units between “°F” and “°C”.
S
ET
(
M
ENU
)
M
ODE
Содержание VX-3R
Страница 29: ...VX 3R OPERATING MANUAL 27 REPEATER OPERATION NOTE...
Страница 127: ...VX 3R OPERATING MANUAL 125 NOTE...