User’s Manual
72
-
Submit/Update >
When done, move the cursor to this item and press ENTER to submit the
settings.
NOTE:
If there are two
XDVR2
units set the same domain name, the
later setting will not be submit successfully.
5.1.7
RS485 Setup >
This menu allows setting up the parameters of the unit’s RS-485
communications port. From the Main menu, select <RS485 Setup> and press
ENTER. The following menu is displayed.
RS485 Setup
1. Unit ID
2. Baud Rate
3. Bits
4. Stop
5. Parity
224
9600
8
1
None
5.1.7.1 Unit ID >
This item is used to change the RS-485 ID address of the unit. The ID is in the
range of <1> to <255>. The default is <224>.
5.1.7.2 Baud Rate >
The Baud rate options for associated with the protocol are <2400>, <4800>,
<9600>, <19200> and <38400>. The default is <9600> baud.
5.1.7.3 Bits >
User can specify the bits in a word that are associated with this protocol. The
available options are <6>, <7> and <8> bits. The default is <8> bits.
5.1.7.4 Stop >
User can specify the stop bit associated with this protocol. Options are <1>
and <2> stop bits. The default is <1> stop bit.