V5 series inverter
60
When P0.01
(
Frequency setting chanel
)
= 8, set the frequency setting channel combination via P3.00.
0: VI
+
CI
1: VI
-
CI
2: External pulse
+
VI
+
Increase/Decrease key
3: External pulse
-
VI
-
Increase/Decrease key
4: External pulse
+
CI
5: External pulse
-
CI
6: RS485
+
VI+Increase/Decrease key
7: RS485
-
VI
-
Increase/Decrease key
8: RS485
+
CI+Increase/Decrease key
9: RS485
-
CI-Increase/Decrease key
10: RS485
+
CI
+
External pulse
11: RS485
-
CI
-
External pulse
12: RS485
+
VI
+
External pulse
13: RS485
-
VI
-
External pulse
14: VI
+
CI
+
Increase/Decrease key
+
Digital setting P0.02
15: VI
+
CI
-
Increase/Decrease key
+
Digital setting P0.02
16: MAX (VI, CI)
17: MIN (VI, CI)
18: MAX (VI, CI, PLUSE)
19: MIN (VI, CI, PLUSE)
20: VI, CI is avalid, VI is priority
P3.01
Parameter initialization lock
Range: lowest bit 0~2, ten bit ~2
00
LED lowest bit:
0: All the parameters can be modified.
1: other parameters cannot be modified except this parameter.
2: Only P0.02 and P3.01 can be modified.
LED ten bit:
0: invalid
1: Restore to default setting
2: Clear fault record
Note:
(1) The default setting of P3.01 is 0 and allows all the parameters to be modified. Please set it to 0 before you want
to modify function code. If it is need to protect the parameters, please set this parameter to required protection
level.
(2) P3.01 will be changed to 0 automatically after restoring to default setting.
P3.02
Parameter copy (this function is developing)
Range: 0, 1, 2
0
0: Disabled
1: Parameter upload:
Upload the parameters from inverter to remote opration panel.
2: Parameter download:
Download the parameters from remote operation panel to inverter.
Note: This function is still in developing.
P3.03
Auto energy-saving running
Range: 0, 1
0
0: Disabled
1: Enabled
Inverter can saves the energy through detecting the load current; adjust output voltage when motor has no load or light load
running. This function is used to the situation of stable load and speed.
P3.04
AVR funciton
Range: 0, 1, 2
0
Содержание V5