CAN FD v2.0
53
PG223 December 5, 2018
Chapter 2:
Product Specification
RB*-ID Register (Address 0x2100, 0x2148 …0x4100,
0x4148 …)
RB1 to RB63 Message Space
0x4148-
0x418C
RB1_1
Read Only
0x4190-
0x41D4
RB2_1
Read Only
:
:
0x49B8-
0x49FC
RB31_1
Read Only
:
:
0x52B8-
0x52FC
RB63_1
Read Only
Notes:
1. Read from uninitialized memory location might return X or invalid data. Asserting a soft or hard reset does not
clear block RAM locations.
2. Message Buffer element resides in RX block RAM. Host should respect read access rules to avoid memory
collisions.
Table 2-39:
RB ID Register
Bits
Name
Control/
Status
Default
Value
Description
31:21
ID[28:18]
Status
N/A
Standard Message ID.
The Identifier portion for a Standard Frame is 11 bits.
These bits indicate the Standard Frame ID.
This field is valid for both CAN and CAN FD Standard and
Extended Frames.
20
SRR/RTR/
RRS
Status
N/A
Substitute Remote Transmission Request.
For Extended CAN frames and Extended CAN FD frame this bit
was received at SRR position of the respective frame.
For Standard CAN FD frame this bit was received at RRS
position of the frame.
This bit differentiates between received standard CAN data
frames and standard CAN remote frames as following
• 1 = Indicates that the received message is a Standard
Remote CAN Frame.
• 0 = Indicates that the received message is a Standard Data
CAN Frame.
Table 2-38:
CAN FD RX Message Space (Sequential/FIFO Buffers - RX FIFO-1)
(Cont’d)
Start
Address
Name
Access
Description
Notes