31
Set up and operation for DC PULSE TIG Welding
EXAMPLE OF PULSE DC TIG WELDING - SETUP PARAMETERS:
Material = Stainless Steel x 2.0mm / Tungsten Electrode = 1.6mm 2% Thoriated / Gas = Argon
The following steps are a guide as a starting point for you to set the machine up in Pulse mode to give an
example of welding in Pulse mode function. You can experiment by changing any of the variables to see
what effect it has over the welding and what the end result can be, but it is suggested to change only one
variable at a time and then check the welding to see what the result is, in this way you acquire a better un-
derstanding of how each variable affects the welding current.
100A
30A
Peak
Amp
Base
Amp
DC Pulse Welding Set Up Procedure
Razor
32OAC/DC
TIG-MMA
1. Select DC Pulse Mode
Select DC Pulse welding
mode by the pushing the
PULSE button to select
and illuminate the pulse
icon.
Peak Amp: Select by
turning the encoder to
cycle through to illuminate
the Peak Amp icon.
2. Select Peak Amperage
Turn the Encoder to
set Peak Amperage
The setting shows on the digital
display.
Push the Encoder to
lock the icon ready for
adjustment.
Turn the Encoder to
set Base Amperage
The setting shows on the digital
display.
Push the Encoder to
lock the icon ready for
adjustment.
Base Amp: Turn the
encoder to cycle through
to illuminate the Base
Amp icon.
3. Select Base Amperage
Turn the Encoder to set
the Base Amperage
Push the Encoder to
lock the icon ready for
adjustment.
Base Amp: Turn the
encoder to cycle through
to illuminate the Base
Amp icon.
4. Select Pulse Frequency Hz
Peak
Amp
Base
Amp
100A
30A
100A
30A
Selecting Pulse Parameters
Select pulse parameters by turning the
encoder to cycle through the front
panel to select the pulse parameter
icons and make settings as show in the
following step by step procedure.
Turn the Encoder to set
the Base Amperage
Push the Encoder to
lock the icon ready for
adjustment.
Pulse %: Turn the
encoder to cycle through
to illuminate the Pulse
%
icon.
5. Select Pulse Width
100A
30A
Peak
Amp
Base
Amp
100A
60%
30A
40%
Peak Amp
On Time
Pulse Width
Time = 1 Second (Hz)
Time = 1 Second (Hz)
The value selected is the number
of times the current switches
from Peak Amp to Base Amp per
second
The value selected is the % of
time the Peak Amp is on during
each pulse cycle.