DC HF TIG Welding Standard Set Up Procedure:
9). Step by Step procedure for Basic HF DC TIG Welding - Front panel settings.
Razor
32OAC/DC
TIG-MMA
Select DC TIG by pressing the
TIG button until the DC icon il-
luminates.
Select 2T or 4T trigger function
as required by the pushing the
TORCH MODE button to cycle
through the trigger options. The
icon will illuminate for the selected
trigger option.
Select HF or LIFT ARC arc igni-
tion required by the pushing the
HF- LIFT ARC button to cycle
through the options. The icon will
illuminate for the selected arc igni-
tion option.
1. Select DC Tig Function.
2. Select Torch Mode.
3. Select Arc Ignition
4. Select DC Mode
Select DC straight welding mode
(non pulse) by the pushing the
PULSE button to select and il-
luminate the no pulse
icon.
Turn the Encoder to set
the Tungsten diameter
Select by turning the encoder knob to cycle through
to illuminate the icon.
Push the Encoder to
lock the icon ready for
adjustment.
The value selected shown on the
digital display represents the % of
time that the Peak Amp is on dur-
ing the pulse cycle.
5. Select Tungsten Diameter
Turn the Encoder to set
the Pre-Gas Time
Pre Gas Time: Select by turning the encoder to cycle
through to illuminate the Pre Gas Timer icon.
The value selected shows
on the digital display. It is the
length of time the gas will
flow before the arc starts.
Push the Encoder to
lock the icon ready for
adjustment.
6. Select Pre Gas
Turn the Encoder to set
the Start Amp value
Start Amp: Select by pushing the encoder to cycle
through to illuminate the Start Amp icon.
The value selected shows on the
digital display. It is the amount
of amps the machine will deliver
at the start of the weld.
Push the Encoder to
lock the icon ready for
adjustment.
Turn the Encoder to set
the Up Slope value
The set value shows on the digital
display. It is the time the welding
current takes to rise from start
amps to welding amperage.
Push the Encoder to
lock the icon ready for
adjustment.
Up Slope Time: Select by turning the encoder to
cycle through to illuminate the Up Slope icon.
7. Select Start Amps