18
Continued - Weld Program Selection & Setting
Razor
32OAC/DC
TIG-MMA
6D
- SPOT Weld Program -
Selecting SPOT Weld program parameters
Parameter selection: Select by turning the
Encoder Knob to cycle
through the weld parameter icons.
The icon will illuminate when selected.
Push the encoder knob to lock the icon. The LED icon will blink on
and off ready for adjustment of the parameter.
Turn the Encoder
to adjust the setting. Push the Encoder to
lock the setting.
SPOT WELD: Select by pushing
the button to cycle through
to illuminate the icon.
Turn the Encoder to set
the SPOT ON time value
Range is (0.01 - 1.0 sec)
SPOT ON TIME: Select by turning the encoder
knob to cycle through to illuminate the icon.
Push the Encoder to
lock the icon ready for
adjustment.
The value selected shown on
the digital display represents the
amount of time the welding current
stays on after the trigger has been
pressed and the arc established.
SPOT ON TIME -
Provides selection and adjustment of the ON TIME of the weld during SPOT Weld cycle.
Adjusts the amount of time the welding output stays on after arc igintion.
SPOT MODE -
Selecting SPOT mode allows setting of an ON time and OFF time of the welding cuurent. After pressing
the torch switch and generating an established arc the welding current will stay on for the amount of ON TIME, (
set in the SPOT
weld program
) the arc will go out after the set amount has passed. Keeping the torch switch depressed will allow an OFF TIME
(
interval
) (
set in the SPOT weld program
) period before the arc is re-established and the welding current stays on again for the set
amount of ON TIME, the cycle will repeat until the torch switch is released.
Turn the Encoder to set
the SPOT ON time value
Range is (0.1 - 5.0 sec)
SPOT OFF TIME: Select by turning the encoder
knob to cycle through to illuminate the icon.
Push the Encoder to
lock the icon ready for
adjustment.
The value selected shown on
the digital display represents the
amount of time the welding current
stays off during the SPOT weld
cycle.
SPOT OFF TIME -
Provides selection and adjustment of the OFF TIME of the weld during SPOT Weld cycle.
Adjusts the amount of the OFF time interval of the welding current.