Front Panel Operation
Razor
32OAC/DC
TIG-MMA
Weld program function selection and adjustment
Turning the encoder knob will allow cyclic step by step motion through the weld program, the encoder can be turned in both direc-
tions allowing backward and forward travel through the weld program functions. When the LED lands on the desired function
push the encoder knob, this will lock the function ready for adjustment of its parameter, the LED will blink on and off
to show the function selected. Turning the encoder will allow adjustment of the parameter which will be shown in the
Digital Display on the front panel of the machine.
Pushing the encoder after adjustment will set the parameter and return it to cylic travel through the program.
IMPORTANT:
When the encoder is in set parameter mode, ie LED blinks on and off. It will time out after 5 seconds of last use and
return to cyclic mode.
Using the ENCODER to Select Weld Program Functions and Adjust Settings
Parameter selection: Select by turning the Encoder
Knob to cycle
through the weld parameter icons.
The icon will illuminate when selected.
Push the encoder knob to lock the icon. The LED icon will blink on
and off ready for adjustment of the parameter.
Turn the Encoder
to adjust the setting. Push the Encoder to
lock the setting.
6A
- Weld Program -
Selecting weld program parameters
Turn the Encoder to set
the Start Amp value
(Range is 10-320A)
Start Amp: Select by pushing the encoder to cycle
through to illuminate the Start Amp icon.
The value selected shows on the
digital display. It is the amount
of amps the machine will deliver
at the start of the weld.
Start Amp -
Provides selection for the amount of amperage required at the start of the weld.
Turn the Encoder to set
the Pre-Gas Time
(Range is 0.5-10 Sec)
Pre Gas Time: Select by turning the encoder to cycle
through to illuminate the Pre Gas Timer icon.
The value selected shows
on the digital display. It is the
length of time the gas will
flow before the arc starts.
Pre Gas Timer -
Provides selection for gas flow time prior to the arc starting.
Push the Encoder to
lock the icon ready for
adjustment.
Push the Encoder to
lock the icon ready for
adjustment.
Turn the Encoder to set
the Up Slope value
(Range is 0-15 Sec)
The set value shows on the digital
display. It is the time the welding
current takes to rise from start
amps to welding amperage.
Up Slope Time -
Sets the transition time from Start Amperage to Welding Amperage
Push the Encoder to
lock the icon ready for
adjustment.
Up Slope Time: Select by turning the encoder to
cycle through to illuminate the Up Slope icon.