44
Freedom SW Owner’s Guide
Configuring the Freedom SW using the SCP
An overview of the Freedom SW advanced settings menu structure is
shown below and the next page.
Figure 22
Menu Map of the Freedom SW Advanced Settings 1
FSW3012 00: Chg Settings
Batt Type
Custom Settings
Batt Capacity
Max Chg Rate
Charge Cycle
ReCharge Volts
Absorb Time
Auto Chg Enable
Default Batt Temp
[Flooded]
[440Ah]
[100%]
[3-Stage]
[12.5V]
[180min]
[Enabled]
[Warm]
[*Flooded] [Gel] [AGM] [Custom]
[*3-Stage] [2StgNoFloat]
[*Enabled] [Disabled]
[*Warm] [Hot] [Cold]
FSW3012 00: Setup
Mode
Battery
Load
AC In
Advanced Settings
Inverter
Search Mode
Charger
Force Chg State
Equalize
Desired Mode
Clear Faults Warnings
View Device Info
Invert
11.8V -88.0A N/A
915W 120V 7A
0V 0A 0Hz
[Enabled]
[Disabled]
[Disabled]
[Disabled]
[Standby]
Status
Configur
able Sett
ings
FSW3012 00: Dev Info
View Fault Log
View Warning Log
View Event Log
FSW3012 00: Adv Settings
Inverter Settings
Charger Settings
AC Settings
GEN Support
Stacking
Restore Defaults
Adv Features
FSW3012 00: Inv Settings
Low Batt Cut Out
LBCO Delay
Hi Batt Cut Out
Search Watts
Search Delay
[11.0]
[10sec]
[15.5V]
[50W]
[2sec]
FSW3012 00: Cust Settings
Eqiz Support
Eqiz Voltage
Bulk Voltage
Absorb Voltage
Float Voltage
BattTempComp
[Enabled]
[16.0V]
[14.4V]
[14.4V]
[13.5V]
[-27mV/K]
[*Enabled] [Disabled]
[*Disabled] [Enabled]
[*Disabled] [Enabled]
[*No Float] [Float] [Bulk]
[Disabled]
[*Standby] [Operating]
1
1
Appears only when
Equalize support is Enabled.
Freedom SW 3K2K InvChg Owners Guide.book Page 44 Wednesday, October 9, 2013 1:34 PM
Содержание Freedom SW 815-2024
Страница 2: ...Freedom SW 3K2K InvChg Owners Guide book Page ii Wednesday October 9 2013 1 34 PM ...
Страница 14: ...Freedom SW 3K2K InvChg Owners Guide book Page iv Wednesday October 9 2013 1 34 PM ...
Страница 95: ...Freedom SW 3K2K InvChg Owners Guide book Page i Wednesday October 9 2013 1 34 PM ...