Operating the Freedom SW with the SCP
Item Description
1
AC In/Charge
light indicates that qualified AC is present
at the input of an inverter/charger. When the Freedom SW
is connected to a qualified AC source like the utility grid
or a generator, this light on the SCP illuminates.
2
Inverter On
light illuminates when the Freedom SW is
inverting using battery power.
3
Low Battery
light
illuminates when the battery voltage on
the Freedom SW is low.
4
Fault
light
indicates a condition that requires user
attention and intervention. The Fault light illuminates
when any Xanbus-enabled device connected to the
network is in fault. See “Fault Types” on page 67 for the
definitions of a fault and warning.
5
STBY/ON Fault Clear
button
is used to clear active faults
on the system if pressed momentarily. It also toggles all
Xanbus-enabled devices on the system between
Operating and Power Save (Safe) mode when held down
for more than five seconds. See “Inverter Operation
Using the Front Panel” on page 12.
6
Screen
displays menus, settings, and system information.
Displays a menu screen title, four lines of menu items,
and a line that contains small arrows that depict pointers
to SCP buttons.
7
Func
button:
•
Cancels selection of a menu item.
•
Returns you to the previous screen.
•
Changes the functions of the Up and Down arrow
buttons.
8 (
and
9)
Down (
and
Up) arrow buttons:
•
Scrolls down (up) one line of text.
•
Decreases (increases) a selected value.
When the
Func
button is pressed to select:
•
“
Shr
” - the down (and up) arrow buttons increment
(decrement) shore power breaker capacity on a
Freedom SW inverter/charger
a
.
•
“
AGS
” - the down (and up) arrow buttons switch
between different AGS Start modes (Auto, Manual-
On, Manual-Off).
•
“
Home
” - the down (and up) arrow buttons enable or
disable the inverter.
See “Soft Key Navigation” on page 20 for more
information.
10
Enter
button:
•
Confirms selection of a menu item.
•
Moves you to the next screen.
a. If the Freedom Sequence power manager is installed in the power system, the shore breaker capac-
ity on the power manager is adjusted but not the inverter/charger.
Item Description
Freedom SW 3K2K InvChg Owners Guide.book Page 17 Wednesday, October 9, 2013 1:34 PM
Содержание Freedom SW 815-2024
Страница 2: ...Freedom SW 3K2K InvChg Owners Guide book Page ii Wednesday October 9 2013 1 34 PM ...
Страница 14: ...Freedom SW 3K2K InvChg Owners Guide book Page iv Wednesday October 9 2013 1 34 PM ...
Страница 95: ...Freedom SW 3K2K InvChg Owners Guide book Page i Wednesday October 9 2013 1 34 PM ...