26
Freedom SW Owner’s Guide
Operating the Freedom SW with the SCP
Table 3
Device Setup Screen Status Information
Line 1
Label
: “
FSW3012 00: Setup
”
Line 2
Label
:
Mode
Field 1
: Freedom SW operating mode or “operating state”
(see Table 4 on page 27).
Line 3
Label
:
Battery
Field 2
: Total battery current. Negative value if the battery is
discharging and positive value when charging.
Field 3
: Battery voltage
Field 4
: Battery temperature. Displays the highest temperature when
reading multiple inverters that are installed. Displays
N/A
when
there is no BTS attached.
FSW3012 00: Setup
Mode
Battery
Load
AC In
Invert
11.9V -8.8A N/A
915W 120V 7A
0V 0A 60Hz
Line 1
Line 2
Line 3
Line 4
Line 5
Field 2
Field 1
Field 5
Field 3
Field 4
Field 6
Field 7
Field 8 Field 9 Field 10
Line 4
Label
:
Load
Field 5
: Total power drawn by AC loads connected to the unit.
Field 6
: Inverter output voltage at load terminals of one inverter/
charger unit.
Field 7
: Sum of all current drawn out by the AC loads.
Line 5
Label
:
AC In
Field 8
: AC input voltage at AC In terminals of the inverter/charger.
Field 9
: Sum of all current drawn into one inverter/charger unit.
Field 10
: AC input frequency
STBY/ON Fault Clear
button
Press momentarily to clear all faults on all devices on the network.
Press and hold for five seconds to switch all devices in the network
between operating and safe modes.
Enter
,
Up arrow
,
Down arrow
buttons
(pressed
simultaneously)
Switches between Basic Settings and Advanced Settings.
Table 3
Device Setup Screen Status Information
Freedom SW 3K2K InvChg Owners Guide.book Page 26 Wednesday, October 9, 2013 1:34 PM