97-0019-01-01
39
Configuring the Freedom SW using the SCP
Table 6
Setting Defaults and Ranges
Model
Freedom SW 2012 / 3012
Freedom SW 2024 / 3024
Item
Default
Min
Max
Default
Min
Max
Batt Type
Flooded
Flooded, Gel,
AGM, Custom
Flooded
Flooded, Gel,
AGM, Custom
Batt Capacity
2000-watt models
250Ah
50Ah
2000Ah
250Ah
50Ah
1000Ah
Batt Capacity
3000-watt models
440Ah
440Ah
Max Chg Rate
100%
10%
100%
100%
10%
100%
Charge Cycle
3Stage
3Stage,
2StgNoFloat
3Stage
3Stage,
2StgNoFloat
ReCharge Volts
12.5V
11.0V
13.5V
25.0V
22.0V
27.0V
AC1 Breaker
30A
5A
30A
30A
5A
30A
Low Batt Cut Out
10.5V
10.0V
12.0V
21.0V
20.0V
24.0V
Table 7
Basic Settings
Item
Description
Batt Type
Sets the system battery chemistry and type:
Flooded
,
AGM
,
Gel
, and
Custom
.
Selecting
Custom
displays the
Custom Settings
item, which
allows you to adjust the settings for each charging stage.
Batt Capacity
Selects the system battery capacity in amp hours. Setting the battery
capacity to 0 resets the charging current to its default values.
Zero Ah battery capacity implies there is no absorption exit current
criteria and absorption only exits when the absorption timer (default
3hrs, range 1min-8hr) expires.
Max Chg Rate
Sets the percentage of the maximum DC output current that is
available to the charger. The maximum DC output current for
different models is:
•
Freedom SW 2012 —100 ADC
•
Freedom SW 3012 —150 ADC
•
Freedom SW 2024 —50 ADC
•
Freedom SW 3024 —75 ADC
If multiple Freedom SWs are charging the same battery bank, set
each inverter's
Max Chg Rate
to 1/n of the desired charge rate
(where n is the number of inverter/chargers).
Charge Cycle
Sets the charging method:
3-Stage
(bulk, absorption, float) or
2StgNoFloat
(bulk, absorption, no float).
ReCharge Volts
Sets the recharging volts to tell the charger to initiate charging when
the battery drains past the value setting.
AC In Breaker
Set the breaker limit of incoming AC.
Low Batt Cut Out
Low Battery Cut Out (LBCO) controls when the inverter stops
producing AC output due to a low battery voltage condition. The
inverter will stop producing AC output only after this level has been
reached for the period of time set by the
LBCO Delay
. This setting is
not temperature compensated.
Freedom SW 3K2K InvChg Owners Guide.book Page 39 Wednesday, October 9, 2013 1:34 PM
Содержание Freedom SW 815-2024
Страница 2: ...Freedom SW 3K2K InvChg Owners Guide book Page ii Wednesday October 9 2013 1 34 PM ...
Страница 14: ...Freedom SW 3K2K InvChg Owners Guide book Page iv Wednesday October 9 2013 1 34 PM ...
Страница 95: ...Freedom SW 3K2K InvChg Owners Guide book Page i Wednesday October 9 2013 1 34 PM ...