38
Freedom SW Owner’s Guide
Configuring the Freedom SW using the SCP
An overview of the Freedom SW menu structure is shown below. The SCP
displays the Freedom SW basic settings menu.
Figure 20
Menu Map of the Freedom SW Basic Settings
FSW3012 00: Setup
Mode
Battery
Load
AC In
Inverter
Search Mode
Charger
Force Chg State
Equalize
Desired Mode
Clear Faults Warnings
View Device Info
Basic Settings
Invert
11.8V -88.0A N/A
915W 120V 7A
0V 0A 0Hz
[Enabled]
[Disabled]
[Disabled]
[Disabled]
[Standby]
Status
Configur
able Sett
ings
FSW3012 00: Dev Info
View Fault Log
View Warning Log
View Event Log
FSW3012 00: Basic Settings
Batt Type
Batt Capacity
Max Chg Rate
Charge Cycle
ReCharge Volts
AC In Breaker
Low Batt Cut Out
[Flooded]
[440Ah]
[100%]
[3-Stage]
[12.5V]
[30A]
[11.0V]
[*Enabled] [Disabled]
[*Disabled] [Enabled]
[*Disabled] [Enabled]
[*No Float] [Float] [Bulk]
[Disabled]
[*Standby] [Operating]
[*Flooded] [Gel] [AGM] [Custom]
[*3-Stage] [2StgNoFloat]
Follow procedures on “To select and change a
configurable setting:” on page 33 to change the settings.
Freedom SW 3K2K InvChg Owners Guide.book Page 38 Wednesday, October 9, 2013 1:34 PM