Page: 18
SmartPad LCD
¥
© 2006 Xantech Corporation
Caution:
Power voltage for the keypad is transmitted along this cable!
Incorrect wiring on this cable can
destroy the CM8X8/MRC Keypad and/or the CSPLCD Display!
Be sure to test cable for proper connections
before
making connections.
Expansion:
This port is used to connect the CSPLCD to an additional CM8X8/MRC88 Keypad. Connect using CAT5
cable terminated at both ends with RJ45 connectors (using the EIA/TIA 568B standard) from the
EXPANSION connector (
Figure 3 – 14)
on the rear of the CSPLCD Display into the RJ45 connector
marked “Controller” on the rear of the CM8X8/MRC88 keypad.
Note:
The Zone Termination Jumper (
Figure 3 – 16)
needs to be removed in this configuration and the
12V
Out to Expansion
jumper (
Figure 3 – 15)
needs to be installed.
S
ERIAL
RS422/232 P
ORT
W
IRING
:
(Figure 3 – 21)
This is a bi-directional RS422 port that can be run up to 4000ft. (1.2KM) to communicate with a remote
RS232 device. Use CAT5 cable terminated in RJ45 connectors. The RS422232 converter (sold separately)
and a 12VDC Power Supply are required located at the remote location within 30ft of the RS232 device to
be controlled.
Note:
Null Modem Adaptor may be necessary for proper communication. Please consult manufactures
specification of device being controlled.
DB9 Pin Out
Function
2
Rx
3
Tx
5
GND
RS422232 DB9 Pin Out
IR I
N
Z
ONE
:
(Figure 3 – 18)
To wire
local
emitters in-the-zone (emitters used to control components in the same general area as the
SmartPad LCD), wire the IR OUT and GND terminals on the rear of the CSPLCD Display to the IR (white
stripe) and GND of the emitter cable. To control numerous components in the same area, wire these
terminals to an amplified connecting block (Xantech Model 791-44) using 18-20AWG 2-conductor cable. A
2-conductor screw-type removable connector is provided.
Note:
IR In Zone port is an CM8X8/MRC88 feature. This is active only when enabled in the MRC88 DragMRC
Software or Universal Dragon Software.
Содержание CSPLCD39G
Страница 28: ...Page 28 SmartPad LCD 2006 Xantech Corporation Figure 15 Building The GUI Screen...
Страница 33: ...Commercial SmartPad LCD Page 33 2006 Xantech Corporation Figure 19 Built In Mfg s IR Command Library...
Страница 49: ...Commercial SmartPad LCD Page 49 2006 Xantech Corporation Figure 29 Sense Trigger Setup...
Страница 59: ...Commercial SmartPad LCD Page 59 2006 Xantech Corporation Figure 37a MRC88 Toggle Power Programming...
Страница 60: ...Page 60 SmartPad LCD 2006 Xantech Corporation Figure 37b CSPLCD MRC88 Zone Toggle Power Programming...
Страница 78: ...NOTES...
Страница 79: ...NOTES...
Страница 80: ...Page 78 SmartPad LCD 2006 Xantech Corporation...