Start signal
Command | 0x40
Length
Status
CS
0x02
0x42
0x01 0x00
1 Byte
1 Byte
Status:
0x00:
Request received, will go to sleep now
0x01:
Operation failed
0xFF:
Operation not permitted
Please note that the
pin has a second function.
If the mod-
ule is not in
ACTION_SLEEP
mode and the UART was disabled using the
, the UART can be re-enabled by applying falling edge,
holding the line low for at least 10ms before applying a rising edge and
holding it high for at least 10ms. In this case the module answers with a
message.
7.5.4. CMD_SLEEP_IND
This indication is send by the module when the
has expired without
a connection to the module.
Format:
Start signal
Command
Length
Status
CS
0x02
0x82
0x01 0x00
0x00
1 Byte
Status:
0x00:
Advertising timeout detected, will go to sleep now
7.5.5. CMD_FACTORYRESET_REQ
This command triggers a factory reset of the module. First, the default User Settings are
restored, then the module is reset.
Please note that also the GPIO configuration specified in chapter
is reset to
default.
Format:
Start signal
Command
Length
CS
0x02
0x1C
0x00 0x00
0x1E
Response (
Proteus-III reference manual version 1.3
© August 2020
www.we-online.com/wireless-connectivity
84