7.7.10. CMD_GPIO_REMOTE_WRITE_IND
This command indicates that the remote device has written the free GPIOs of the radio
module.
Please note that only the GPIOs are part of this message, that have been
updated successfully. Failed attempts of GPIO updates will not be indicated by
this message.
Format:
Start signal
Command
Length
Block
1
. . .
Block
n
CS
0x02
0xA9
2 Bytes
x Bytes
x Bytes
1 Byte
The
Block
structure is as defined in
CMD_GPIO_LOCAL_READ_CNF block structure
7.7.10.1. Example: GPIOs have been written via remote access
Start signal
Command
Length
Status
Block
1
Block
2
CS
0x02
0xA9
0x07 0x00
0x00
0x02
0x01
0x00
0x02
0x02
0x01
0xAE
The remote device has written the GPIOs with GPIO_ID
0x01
(GPIO is low) and
0x02
(GPIO
is high).
Proteus-III reference manual version 1.3
© August 2020
www.we-online.com/wireless-connectivity
111