8.23. DIS_ModelNumber: Configure the model number
Settings
index
Designation
Permissible
values
Default value
Permissions
Number
of
Bytes
21
See
description
"Default"
read/write
1-64
The user setting
specifies the content of the model number field of the De-
vice Information Service. The permissible characters are in the range of 0x20 - 0x7E which
are special characters (see ASCII table), alphabetic characters (a-z and A-Z), numbers (0-9)
and whitespace.
To add the content of the
to the DIS profile, please set the
corresponding Bit in the
8.23.1. Example 1
Set the model number to "Model1" using
with settings index 21
Start signal
Command
Length
Settings index
Parameter
CS
0x02
0x11
0x07 0x00
0x15
0x4D 0x6F 0x64 0x65 0x6C
0x31
0x7F
Response
: Successfully modified the setting.
Start signal
Command | 0x40
Length
Status
CS
0x02
0x51
0x01 0x00
0x00
0x52
8.23.2. Example 2
Request the model number of the DIS profile using
Start signal
Command
Length
Settings index
CS
0x02
0x10
0x01 0x00
0x15
0x06
Response
: Successfully read out the value "Default".
Start signal
Command | 0x40
Length
Status
Parameter
CS
0x02
0x50
0x08 0x00
0x00
0x44 0x65 0x66 0x61 0x75 0x6C
0x74
0x11
Proteus-III reference manual version 1.3
© August 2020
www.we-online.com/wireless-connectivity