Info
Module A
Module B
⇒
Request
: Send "
EFGH
" to
module B
02 04 04 00
45 46 47
48
0E
⇐
Response
: Request received,
send data now
02 44 01 00 00 47
⇐
Indication
: Received string
"
EFGH
" from
0x55 0x00 0x00 0xDA
0x18 0x00
with RSSI of 0xC1 (-63dBm)
02 84 0B 00
55 00
00 DA 18 00
C1
45
46 47 48
D7
⇐
Response
: Data
transmitted successfully
02 C4 01 00 00 C7
6. Now module A closes the Bluetooth
®
LE connection, so both modules will get a dis-
connect indication message.
Info
Module A
Module B
⇒
Request
: Disconnect
02 07 00 00 05
⇐
Response
: Request
received, disconnect now
02 47 01 00 00 44
⇐
Indication
: Connection
closed
02 87 01 00 16 92
⇐
Indication
: Connection
closed
02 87 01 00 F3 97