Start signal
Command | 0x40
Length
Status
CS
0x02
0x51
0x01 0x00
0x00
0x52
8.8.2. Example 2
Request the security flags of the module using
with settings index 12
Start signal
Command
Length
Settings index
CS
0x02
0x10
0x01 0x00
0x0C
0x1F
Response
: Successfully read out the value 2, which means that the just works
pairing mode is enabled.
Start signal
Command | 0x40
Length
Status
Parameter
CS
0x02
0x50
0x02 0x00
0x00
0x02
0x52
Proteus-III reference manual version 1.3
© August 2020
www.we-online.com/wireless-connectivity