8.10. RF_ScanFlags: Modify the scan behavior
Settings
index
Designation
Permissible
values
Default value
Permissions
Number
of
Bytes
13
See
description
0
read/write
1
This 8-Bit field configures the scan behavior of the module. To use multiple settings, add the
Bit numbers and choose the result as value for
Bit no.
Description
0
If this Bit is set, an active scan is performed when using
. In this
case, after receiving an advertising packet a scan request is send to the advertising
module that returns a scan response containing additional information. For the
communication of Proteus-III modules, active scanning is only needed when using
Beacons. In this case, it is enabled automatically by the firmware. Please note that
active scanning increases the current consumption.
15 : 1
Reserved
Table 19: Scan configuration flags
8.10.1. Example 1
Set the scan flags to 0x01 to enable active scanning using
with settings in-
dex 13
Start signal
Command
Length
Settings index
Parameter
CS
0x02
0x11
0x02 0x00
0x0D
0x01
0x1D
Response
: Successfully modified the setting.
Start signal
Command | 0x40
Length
Status
CS
0x02
0x51
0x01 0x00
0x00
0x52
8.10.2. Example 2
Request the scan flags of the module using
with settings index 13
Start signal
Command
Length
Settings index
CS
0x02
0x10
0x01 0x00
0x0D
0x1E
Response
: Successfully read out the value 0, which means that active scan is
disabled.
Proteus-III reference manual version 1.3
© August 2020
www.we-online.com/wireless-connectivity
131