MedWeld 5000 Technical Reference Manual
6 - 1
M-032170
Setup Parameters
6
The MedWeld 5000 provides a number of programmable setup
parameters. They allow for customizing the control to meet your
application requirements.
These parameters "inform" the control about its operating environment.
They also define the hardware (such as the type of transformer used and
its turns ratio), and describe acceptable limits on the ranges of weld
parameters (such as secondary current, power factor and C-factor).
Some parameters define the severity of fault conditions (as either
FAULT or ALERT). They tell the control how to respond when it
detects a fault condition:
•
FAULT tells the control to turn OFF the NO FAULT output, or turn
ON the FAULT output. This indicates that a fault condition was
detected. Fault conditions normally inhibit initiation of a weld
schedule.
•
ALERT tells the control to activate the ALERT output. An alert
condition generally will not inhibit initiating a weld schedule.
•
NONE tells the control to log that the condition was detected, but
neither output is activated. This condition will not inhibit initiation
of a weld schedule.
Parameter settings are programmable (with some exceptions). However,
the list of parameters is fixed. You CANNOT remove a parameter from
this list.
You can change the value assigned to a parameter from the DEP-100S
Programming Device, or WebView.
NOTE:
To protect the operator or equipment, some parameters are NOT
programmable. For these, you CANNOT change the setting or value.
Содержание MedWeld 5000
Страница 2: ...MedWeld 5000 Technical Reference Manual Modified 1 31 06 M 032170...
Страница 6: ...MedWeld 5000 Technical Reference Manual Modified 1 31 06...
Страница 38: ...Installing the MedWeld 5000 2 12 MedWeld 5000 Technical Reference Manual M 032170...
Страница 82: ...Advanced Software Features 5 12 MedWeld 5000 Technical Reference Manual M 032170...
Страница 120: ...Hardware Troubleshooting 9 10 MedWeld 5000 Technical Reference Manual M 032170...