Hardware Troubleshooting
MedWeld 5000 Technical Reference Manual
9 - 3
M-032170
Weld Processor
Symptom
Probable Cause
Corrective Action
Inadequate or no
power to the timer
unit
(Power supply LED is
on)
Bad connectors or improper
seating of power supply
and/or timer unit in the
chassis.
Remove power and inspect the power
supply and timer unit connections.
Remove power from the chassis and
re-seat modules.
Power has been cycled too
fast, causing a large current
inrush resulting in a thermal
overload.
Remove power from the rack for AT
LEAST two minutes. Then restore
power.
Blown fuse on the power
supply.
Check the fuse. Replace if blown.
Line power is not con-
nected to the power supply.
Verify that line power is connected to
the power supply.
Improper voltage jumper
setting.
Check the jumper setting to verify that it
matches the input voltage.
Loss of RAM memory
(
Batt LED is on)
The battery on the timer
unit is low or dead.
Replace the battery on the timer.
(The
battery is soldered in place. Only quali-
fied personnel should attempt battery
replacement in an ESD-safe environ-
ment.)
Timer cannot com-
municate (
CPU Fault
LED on processor is
on)
Bad connectors or improper
seating of the timer unit in
the chassis.
Remove power. Inspect timer unit con-
nections. Then cycle power.
Remove power from the chassis, re-
seat modules and restore power.
Timer firmware incompati-
ble.
Verify compatibility; correct as needed.
If not known, consult your WTC
representative for assistance.
Содержание MedWeld 5000
Страница 2: ...MedWeld 5000 Technical Reference Manual Modified 1 31 06 M 032170...
Страница 6: ...MedWeld 5000 Technical Reference Manual Modified 1 31 06...
Страница 38: ...Installing the MedWeld 5000 2 12 MedWeld 5000 Technical Reference Manual M 032170...
Страница 82: ...Advanced Software Features 5 12 MedWeld 5000 Technical Reference Manual M 032170...
Страница 120: ...Hardware Troubleshooting 9 10 MedWeld 5000 Technical Reference Manual M 032170...