Fault Conditions
8 - 6
PMMK Software F04100
M-032170
Isolation
Contactor Off
When
Needed
Isolation contactor
was not pulled in by
the control when
required by the weld
schedule.
The instruction to activate the
isolation contactor (Function
#88
TURN ON ISOLATION
CONTACTOR
) was missing
from the weld schedule.
Verify that the schedule
contains Function #88
TURN
ON ISOLATION CONTAC-
TOR
.
The timer unit controls the
isolation contactor, which is
driven by a single solid-state
relay. The timer unit signal is
based on status of the CON-
TROL STOP and WELD/NO
WELD Inputs. (Voltage must
be present at these inputs to
allow the timer unit to open or
close the isolation contactor.)
Verify that the Ready to Weld
signal was HIGH (= 1) when
required.
Verify that the Ready to Weld
signal was HIGH (= 1) when
required.
For externally-powered
controls, an internal control
transformer fuse is blown or a
bad external power supply is
causing the fault.
Check fuses and replace as
necessary.
The solid-state relay is faulty.
Replace relay.
The instruction to activate the
isolation contactor was exe-
cuted, but the control was
unable to pull in the contac-
tor, due to incorrect or loose
wiring to the output module.
Check the wiring diagram that
came with your control for
proper I/O designations. Verify
that all wiring connections are
secure.
Faulty output module.
Replace module.
ISO CNTR
ERR-BRKR
TRIPPED
The control has
issued a shunt trip
condition. This fault
will remain until a
fault reset is issued
even if a power cycle
is conducted
A welding condition has
caused the control to shunt
trip to protect the hardware or
a user.
Verify any other welding typ
faults that may appear in the
fault list with a breaker tripped
message. Check the Isolation
contactor for it being stuck
System
Cooling
INVERTER thermal
switch was tripped.
.Loose/incorrect connections
to input module or in circuit.
Check for proper wiring
Insufficient water flow.
Check the water flow, access
holes, hoses and filters (if
used).
Message
Explanation
Possible Cause
Remedy
Содержание MedWeld 5000
Страница 2: ...MedWeld 5000 Technical Reference Manual Modified 1 31 06 M 032170...
Страница 6: ...MedWeld 5000 Technical Reference Manual Modified 1 31 06...
Страница 38: ...Installing the MedWeld 5000 2 12 MedWeld 5000 Technical Reference Manual M 032170...
Страница 82: ...Advanced Software Features 5 12 MedWeld 5000 Technical Reference Manual M 032170...
Страница 120: ...Hardware Troubleshooting 9 10 MedWeld 5000 Technical Reference Manual M 032170...