Setup Parameters
MedWeld 5000 Technical Reference Manual
6 - 3
M-032170
END OF STEPPER:
(FAULT) (ALERT)
The END OF STEPPER fault indicates that a stepper has completed the
last weld in the final step of the assigned stepper. This reflects the state
of either the last stepper initiated, or the last stepper status that was
downloaded.
HIGH CURRENT LIMIT:
(FAULT) (ALERT)
LOW CURRENT LIMIT:
(FAULT) (ALERT)
These faults indicate that the welding conditions during a weld function,
exceeded or fell below the range programmed in the setup parameters.
CONTROL FAILED TO FIRE:
(FAULT) (ALERT)
This condition occurs when the MFDC inverter assembly fails to
properly acknowledge a firing signal from the weld timer during any
weld half-cycle.
EXTENDED WELD:
(FAULT) (ALERT) (NONE)
This fault is generated under one of two conditions, based on which
REWELD function appears in the weld schedule:
•
If the schedule contains the function REWELD IF CURRENT
LESS THAN 00000 AMPS, this indicates that the control was not
able to provide the desired secondary current during the weld, and
performed an unsuccessful reweld.
•
If the schedule contains the function REWELD IF LOW
CURRENT LIMIT FAULT, this indicates that the control
performed a reweld, and the desired current was provided during
the reweld.
ISO CNTR OFF WHEN NEEDED: (FAULT)
The isolation contactor was not pulled in when required by the weld
schedule. This parameter is NOT programmable.
This fault is generated when the control detects that the isolation
contactor is open when it is trying to execute a weld function. (The
contactor must be closed to provide weld current.) A possible cause is
an open L2A or L1AK wire on the SCR.
This fault can also occur if the control detects an absence of voltage
below the contactor when it is closed. A possible cause of the fault is an
open L2A or L1AK wire on the SCR.
On detecting this condition, the control schedules in No Weld and
generates this fault condition. If the control is in No Weld mode, it does
not generate a fault.
ISO CNTR ERR-BRKR TRIPPED: (FAULT)
This fault is generated when the MedWeld 3005 signals to open the
isolation contactor (to cut off weld current) but the isolation contactor
did NOT open. It can also occur if the isolation contactor is pulled in
when a weld initiate is not present.
Содержание MedWeld 5000
Страница 2: ...MedWeld 5000 Technical Reference Manual Modified 1 31 06 M 032170...
Страница 6: ...MedWeld 5000 Technical Reference Manual Modified 1 31 06...
Страница 38: ...Installing the MedWeld 5000 2 12 MedWeld 5000 Technical Reference Manual M 032170...
Страница 82: ...Advanced Software Features 5 12 MedWeld 5000 Technical Reference Manual M 032170...
Страница 120: ...Hardware Troubleshooting 9 10 MedWeld 5000 Technical Reference Manual M 032170...