Setup Parameters
MedWeld 5000 Technical Reference Manual
6 - 9
M-032170
This parameter defines the maximum number of consecutive cycles of
heat conduction. (After nine consecutive cycles without conduction, the
heat cycle counter is reset to zero.)
For seam welding applications, disable this function by setting the cycle
limit to zero.
ISOLATION CONTACTOR DELAY: nn SEC(0–99)
This parameter tells the control how long to hold the isolation contactor
pulled in after the function TURN OFF ISOLATION CONTACTOR
executes. This is designed to prevent wear on the isolation contactor
caused by dropping in and out between welds.
When the ISOLATION CONTACTOR SAVER input is available and
set LOW, it disables this delay timer.
NOTE:
If function #65 (ISOLATION CONTACTOR DELAY) is in the weld
schedule, the function set during the weld schedule will override the
ISOLATION CONTACTOR DELAY setup parameter.
HIGH CURRENT LIMIT WINDOW: nn %(0–99)
LOW CURRENT LIMIT WINDOW: nn %(0–99)
These two parameters define a global current range for every weld
schedule.
The MedWeld 3005 calculates the high current window as a percentage
boost over the current expected. The low current window is a percentage
decrease from the expected current. (The expected current is the base
current—programmed in the weld function—plus the current that the
stepper is providing.)
For ACC, the base is the actual secondary current value programmed.
%I is derived by determining the maximum current deliverable, and the
percentage of that current programmed in the weld schedule.
DATA COLLECTION SAMPLE SIZE: nn
(1–99)
DATA COLLECTION SAMPLE FREQUENCY: nnnn (1–9999)
These two parameters set a global command which allows the weld
control to sample data for analysis at controlled intervals.
The sample size is the amount of weld data collected for analysis
(number of consecutive welds, per bin). The sample frequency is the
total number of welds (per bin) where data is collected (the samples are
taken from).
MAXIMUM TIP DRESSES:
This setup parameter allows the operator to assign a maximum number
of times the electrode tips may be dressed using the setup parameter:
Maximum Tip Dresses. (To disable this feature, set this parameter to
zero. By default, it is set to
000
.) The timer counts the number of tip
dresses made and will output to the DEP when MAXIMUM TIP
DRESSES has been reached.
Содержание MedWeld 5000
Страница 2: ...MedWeld 5000 Technical Reference Manual Modified 1 31 06 M 032170...
Страница 6: ...MedWeld 5000 Technical Reference Manual Modified 1 31 06...
Страница 38: ...Installing the MedWeld 5000 2 12 MedWeld 5000 Technical Reference Manual M 032170...
Страница 82: ...Advanced Software Features 5 12 MedWeld 5000 Technical Reference Manual M 032170...
Страница 120: ...Hardware Troubleshooting 9 10 MedWeld 5000 Technical Reference Manual M 032170...