Fault Conditions
PMMK Software F04100
8 - 3
M-032170
Message
Explanation
Possible Cause
Remedy
Invalid
Sequence
Selected
The combination of
BINARY SELECT
inputs was invalid.
The weld initiate was on but
no BINARY SELECT inputs
were active.
Turn on the BINARY SELECT
input(s) required.
Weld Initiate
Not Present
The WELD INITIATE
input was not active
when checked by the
control in Function
#63
TURN ON
WELD COMPLETE
Weld schedule contains
Function #63
TURN ON
WELD COMPLETE
, but the
function is not required by the
application.
Remove Function #63 from the
weld schedule.
The ROBOT or PLC is not
holding the INITIATE input
high for the amount of time
required by the application.
Repair ROBOT or PLC
program.
Control Stop
The control detected
that the CONTROL
STOP input (normally
HIGH) dropped out.
The CONTROL STOP input
from the ROBOT or PLC was
not active when the control
tried to initiate a weld.
Check/repair ladder logic. Note
if the Control Stop message is
both DIO and DEVICE NET.
The external or internal wiring
(feeding CS1 and CS2) or the
input module is open, causing
a loss of input voltage to the
input.
Check the wiring to verify that
24 VDC or 120 VAC is being
provided to the CONTROL
STOP input.
Stepper
Approaching
Maximum
The linear stepper assigned to the schedule initiated
has started the first weld in the last step.
The electrodes will soon need
maintenance. Dress or replace
the electrodes to avoid the END
OF STEPPER fault condition.
The stepper profile is programmed incorrectly.
Check the stepper profile.
End of
Stepper
A linear stepper in the group # assigned to the sched-
ule initiated completed the last step in the profile.
Dress or replace the electrode
tips. Reset the stepper.
Содержание MedWeld 5000
Страница 2: ...MedWeld 5000 Technical Reference Manual Modified 1 31 06 M 032170...
Страница 6: ...MedWeld 5000 Technical Reference Manual Modified 1 31 06...
Страница 38: ...Installing the MedWeld 5000 2 12 MedWeld 5000 Technical Reference Manual M 032170...
Страница 82: ...Advanced Software Features 5 12 MedWeld 5000 Technical Reference Manual M 032170...
Страница 120: ...Hardware Troubleshooting 9 10 MedWeld 5000 Technical Reference Manual M 032170...