Weld Schedules
MedWeld 5000 Technical Reference Manual
4 - 17
M-032170
The control normally processes all fault conditions at the end of the
weld schedule. This function allows forcing the control to process fault
conditions before it completes the weld schedule. It should appear in the
weld schedule BEFORE any functions that check fault status or require
current weld data.
Caution: This function also causes the control to
calculate the voltage, current and power factor averages
and the C-factor for the weld. It also terminates the
weld summary data collection, to assure the integrity of
the weld data collected.
99
GOTO SEQ#nn (nn = 1-99)
This function is an unconditional jump to another weld schedule. It tells
the control to stop the present weld schedule, and continue with the first
function in another schedule.
This function can be used to save memory space in the control, by
allowing multiple schedules to execute commonly-used functions.
The control considers the schedule originally initiated as the last
schedule. The stepper assigned to the original schedule is also the only
one incremented. This function should appear as the last function in a
schedule, because the control will not return to the original schedule
when it completes the new schedule.
Caution: It is possible to create an infinite programming
loop with Functions #98 (GOTO SEQ #nn IF
CURRENT LESS THAN nnnn0 AMPS) and #99.
Содержание MedWeld 5000
Страница 2: ...MedWeld 5000 Technical Reference Manual Modified 1 31 06 M 032170...
Страница 6: ...MedWeld 5000 Technical Reference Manual Modified 1 31 06...
Страница 38: ...Installing the MedWeld 5000 2 12 MedWeld 5000 Technical Reference Manual M 032170...
Страница 82: ...Advanced Software Features 5 12 MedWeld 5000 Technical Reference Manual M 032170...
Страница 120: ...Hardware Troubleshooting 9 10 MedWeld 5000 Technical Reference Manual M 032170...