Installing the MedWeld 5000
2 - 6
MedWeld 5000 Technical Reference Manual
M-032170
All of these features are programmable from several different
programming devices:
•
Plug the WTC DEP-100S programming device into the connector
on the enclosure door or on the timer unit module.
•
The robot teach pendant.
The flexible I/O allows the operator the ability to program the I/O map
for discrete I/O control or the fieldbus I/O for DeviceNet. Flexible I/O
allows an operator to designate which I/O point is used for a particular
function. For example, if the operator wants to use the input Weld
Initiate, he has the option of putting Weld Initiate on any of the 0-15
inputs he chooses. The flexible I/O should not be in conflict with
another I/O point, this may inhibit the weld control from firing. An
example of conflicting I/O would be having the discrete I/O map and the
FieldBus I/O programmed differently. If the I/O maps for the discrete I/
O and the I/O for the Fieldbus map are identical, the Fieldbus I/O will
take precedance.