PH: 866.476.9217
21
MOTOR UNIT
During maintenance and repair, inspect the fan guard and remove any accumulated
debris from under it and from around the motor and gear. Motor bearings are greased
during assembly. We suggest you inspect and maintain the Unit every six (6) months
but at a minimum it must be done once-a-year due to the usually harsh environment in
which the
GO-E2
Opener operates (temperature extremes, dirty, or moist location,
etc).
1.
The Unit uses sealed bearings; should they need to be replaced, use bearings
of equal quality with a consistency of grease suitable for class of insulation
stamped on nameplate.
The recommended lubricant is: Consistency: #2; Type: Lithium Base; Typical
Grease: SHELL Alvania Grease R3.
GEAR UNIT
The
GO-E2
Opener's gear unit should have the oil changed every 5,000 hours or 1
year. If synthetic lubricant is used, it should be changed every 10,000 hours, or 2 years.
For adverse operating conditions, the interval should be shorter.
1.
The GO-E2 Opener should be checked periodically for increased noise,
surface temperature, vibration, shaft movement and amperage draw.
CAUTION
Keep grease clean. Lubricate motors at
standstill. Remove and replace drain plugs at
standstill. Do not mix petroleum grease and
silicone grease in motor bearings.
CAUTION
Do not mix synthetic and mineral base oils.