PH: 866.476.9217
22
2.
The recommended lubricant for the
GO-E2
Opener's gears is: Type: Oil;
Ambient Temperature Range: -10°F to +100°F; AGMA Lubricant No: 3-4 EP;
ISO Grade: 100-150 EP; Typical Oil: SHELL Omala Oil 100, MOBIL 629.
3.
The oil reservoir holds approximately 1.5 quarts. Actual capacity should be
established by opening the hex head plug from the oil level check port (lower
left side of gear case), and adding oil to top-side oil fill port until oil runs out
of the oil level check port.
4.
Replace the hex head plug in the check port and tighten securely.
5.
Replace the breather/vent plug in the oil fill port and tighten securely.
STORAGE OF GEAR MOTOR
Units shipped are intended to be used within 30 - 60 days after receipt and presumed
to be stored indoors in a heated building.
IMPORTANT
Ambient temperatures below -20°F and above
140°F require special oil seals. Consult your
WORKMASTER Dealer for these applications.
CAUTION
Use only a breather/vent type plug in the oil fill
port.
Units with inspection covers should not be
operated with the inspection cover removed.
Содержание GO-E2
Страница 1: ...GO E2 Gate Opener OPERATOR S GUIDE...
Страница 36: ...PH 866 476 9217 NOTES...
Страница 37: ...PH 866 476 9217 NOTES...
Страница 38: ...PH 866 476 9217 NOTES...
Страница 39: ...PH 866 476 9217 NOTES...