92 | UM-PP-EN-03
Monthly Maintenance
A complete function test of the treadmill must be carried out every 2 - 4 weeks depending on the
duration and intensity of use.
The function test includes the following:
1.
Use the treadmill for a short time at speed of 3.5 - 6 MPH (6 - 10 km/h).
Do unusual noises occur?
2.
Turn up treadmill to max. speed for a short time. Does the treadmill
reach the specified max. speed? Do unusual noises occur?
3.
Does the display correctly show the distance traveled at top speed?
4.
Stop the treadmill and move it to max. incline. Does the treadmill reach
the desired incline?
5.
Do unusual noises occur while the treadmill is running at max. incline?
6.
Check the emergency stop magnetic switch function. Is an emergency
stop initiated?
7.
Check the function of the emergency stop mushroom and/or button.
8.
Set the treadmill to STAND-BY mode. Though slight movement is nor-
mal, the running surface must be very difficult to move. Is the running
surface stopped correctly?
ATTENTION
If there are defects or deviations in the control function, notify
WOODWAY Customer Service immediately.
The device must be taken out of service and disabled until repaired.
Repairs may only be carried out by trained and authorized personnel.
Before starting any maintenance, remove the side panels (NOT electronics covers).
Preventative maintenance consists of the following measures:
•
Clean the inside of the treadmill with a vacuum cleaner. Do not touch the electrical
components (cables, transformers, connectors, etc.).
•
Visually check the drive unit toothed belt (drive belt) for cracks and other wear and missing
or broken teeth.
•
Inspect the aluminum profiles of the slats for damage.
•
Visually inspect all mechanical components for damage (lifting mechanism, welded frame,
side panels, treadmill feet, rollers on the lifting scissors, railings, display, emergency stop
mushroom emergency stop magnetic switch).
•
In rare cases there may be bearing damage. Under certain circumstances this can be
detected through excessive grease leakage from the bearing housing.
•
Have the time limits prescribed by the manufacturer for the maintenance and safety checks
been complied with?
Содержание ST PPS 43 Med
Страница 22: ...16 UM PP EN 03 2 7 EC Declaration of Conformity Fig 1 EC Declaration of Conformity...
Страница 26: ...20 UM PP EN 03 3 5 Dimensions Fig 3 Device dimensions PPS Bari Mill 43 Fig 4 Device dimensions PPS Bari Mill 55...
Страница 27: ...21 UM PP EN 03 Fig 5 Device dimensions PPS Bari Mill 70 Fig 6 Device dimensions PPS Med 43...
Страница 114: ...108 UM PP EN 03 12 Maintenance Report DATE MAINTENANCE MEASURES FROM REMARKS...