80 | UM-PP-EN-03
Adjustment
The height and width of the bar railings are adjusted as follows:
•
Loosen clamping screw on one or both sides (Pos. 3).
•
Set the railing width by moving/rotating the rail (Pos. 1) horizontally to
the desired position.
•
Adjust the height by pressing the knob (Pos. 2) and positioning the railing
at the desired height.
•
Re-tighten clamping screws.
WARNING
Danger of Being Pinched!
In the entry area of the gas spring and the gap between moving
parts, fingers and hands can be pinched.
►
Danger zone is marked with a warning label.
►
Do not touch the danger zones when making adjustments.
7.10
Reverse Directionality
Depending on the model, the treadmill may have a reverse direction function, or may be retrofitted
if necessary. Information is available at a reliable WOODWAY dealer or through WOODWAY Customer
Service.
If the treadmill is equipped with the reverse mode, it can be activated in two different ways. Either
the WOODWAY User-System (WUS) is required or a PC / laptop with installed WOODWAY Treadmill
Control Software, with which the PPS treadmill is connected via the serial communication interface
(RS-232, COM port).
ATTENTION
Provide a Safety Area IN FRONT OF and BEHIND the Device.
When using the reverse direction function, the necessary safety area
of at least 3 ft. W x 6.5 ft. L (1 x 2 m) is to be observed IN FRONT OF
and BEHIND the treadmill (see Section 0 Page 43).
WOODWAY User-System (WUS)
When using reverse direction with the WOODWAY User-System, position the emergency stop switch
(as described in Section 5.6 Page 37) and fix the clip with magnet with pull-cord. Switch the device
on using the STAND-BY button. In the event that a workout is already running, stop the treadmill
using the STOP button. Then press the [-] button on the touch panel.
WOODWAY Treadmill Control Software
When the treadmill is in manual operation mode with the software, a Manual Operation rider appears
in the main window. Below the speed control is the REVERSE DIRECTION key, and the status indicator
for the selected direction (see Fig. 46). Before activating the reverse direction, ensure that the
Содержание ST PPS 43 Med
Страница 22: ...16 UM PP EN 03 2 7 EC Declaration of Conformity Fig 1 EC Declaration of Conformity...
Страница 26: ...20 UM PP EN 03 3 5 Dimensions Fig 3 Device dimensions PPS Bari Mill 43 Fig 4 Device dimensions PPS Bari Mill 55...
Страница 27: ...21 UM PP EN 03 Fig 5 Device dimensions PPS Bari Mill 70 Fig 6 Device dimensions PPS Med 43...
Страница 114: ...108 UM PP EN 03 12 Maintenance Report DATE MAINTENANCE MEASURES FROM REMARKS...