Fire Deck
Service Manual
PG
9
OF
44
M0011.09 APRIL 2019
An ongoing program of product improvement may
require us to change specifications without notice.
WOOD STONE CORPORATION
1801 W. Bakerview Rd.
Bellingham, WA 98226 USA
TOLL FREE
800.988.8103
TEL
360.650.1111
FAX
360.650.1166
woodstone-corp.com
OPERATION SEQUENCE - RFG-IR
*
Note:
Ovens equipped with 2 Radiant Burners will have a third Valve, SV-3, which will be powered at the same time as the SV-2
Valve described above� The operation sequence is identical to that of SV-2� However, be aware that as long as SV-2 or
SV-3 lights, the Dome Flame indicator light will come on and the Controller will power SV-1 as necessary�
BURNER OPERATION SEQUENCES
RFG-IR OVENS - TOUCHPAD CONTROLLER
Pilot lights
Power On
SV-2 Valve powers Igniter and
opens Pilot Valve for radiant (side)
Burner�
Pilot does not light- SV-2 times
out�
SV-2 senses Pilot flame Igniter
off- SV-2 opens- Burner lights-
Dome flame indicator light
comes on�
Radiant Burner remains on until
oven is turned off�
Floor temperature above Hearth
Set Point- Controller does not
power SV-1 (Underfloor IR Burner)�
Floor Temperature below Hearth
Set Point- Controller sends power
to SV-1- SV-1 powers Igniter and
opens Pilot Valve�
Pilot lights- SV-1 senses Pilot
flame- Igniter off- SV-1 opens-
Underfloor Burner lights- Hearth
Heat light on�
Floor reaches the Hearth Set Point
temperature- Controller turns off
power to SV-1 and underfloor IR
Burner shuts off�
Pilot does not light- SV-1 times
out- Touchpad Controller flashes
“chec”�
Содержание FIRE DECK 6045
Страница 41: ...PG 41 OF 44 M0011 09 APRIL 2019 Blank page ...
Страница 43: ...PG 43 OF 44 M0011 09 APRIL 2019 Blank page ...