Fire Deck
Service Manual
PG
21
OF
44
M0011.09 APRIL 2019
An ongoing program of product improvement may
require us to change specifications without notice.
WOOD STONE CORPORATION
1801 W. Bakerview Rd.
Bellingham, WA 98226 USA
TOLL FREE
800.988.8103
TEL
360.650.1111
FAX
360.650.1166
woodstone-corp.com
INFRARED BURNER TROUBLESHOOTING
IR Burner goes out intermittently when
Controller is calling for IR heat�
1.
Check wire connections at the Gas Valve and the Igniter� Remove any wire
ties and uncoil Igniter wires to minimize contact between the wires� Also
check for loose connections at the Controller�
2.
Inspect the Igniter and clean it if necessary� Replace it if damaged�
3.
Check for excessive air movement below the oven� This can cause the
Pilot flame to lift away from the Flame Rod and cause the Burner to go out�
Contact Wood Stone for assistance�
4.
Check the Burner gas pressure, adjust the Valve to achieve the specified
pressure (see Equipment Name Plate)� Check the incoming gas pressure
with the Burner running� If the incoming pressure is OK, but the Burner
pressure is low and will not adjust as high as the pressure specified on the
Equipment Name Plate OR if the Burner pressure is erratic, replace the Gas
Control Valve�
5.
If pressures are OK, replace the Igniter� If problem recurs, replace Gas Valve�
Burner will not light or shuts off
sometimes, and, the Igniter wires are
burned�
1.
Loose Pilot Tube – tighten and replace Igniter
2.
Inadequate oven venting or negative air pressure: See Installation and
Operation Manual� Contact Wood Stone for further assistance�
Wood-Gas Ovens
(W-IR in model #)
IR Burner does not come on�
1.
Verify that gas is being supplied to the oven and that all the air has been
bled from the gas line� If necessary, the gas line may be bled by removing
the inlet plug on the Gas Control Valve� Reinstall the plug when you smell
that gas is present� Allow gas to dissipate before restarting oven�
Do not
leave the oven unattended while the inlet plug is removed!
2.
Verify that the Hearth Set Point is above the Hearth Temperature� If the
Burner does not come on, proceed to step 3 of the RFG-IR troubleshooting
(previous page)�
Probable Cause/Solution