Fire Deck
Service Manual
PG
15
OF
44
M0011.09 APRIL 2019
An ongoing program of product improvement may
require us to change specifications without notice.
WOOD STONE CORPORATION
1801 W. Bakerview Rd.
Bellingham, WA 98226 USA
TOLL FREE
800.988.8103
TEL
360.650.1111
FAX
360.650.1166
woodstone-corp.com
RADIANT BURNER TROUBLESHOOTING
OPERATIONAL OVERVIEW
Wood Stone gas ovens utilize “smart” type Gas
Valves� With these Valves, the ignition module
circuitry is incorporated into the Valve itself—there
is no separate ignition module� Burner ignition
is achieved via a hot surface (Glow Coil) to Pilot
ignition system�
The unit will attempt Pilot ignition for 90 seconds:
30 seconds glow, 30 seconds purge and then 30
seconds with the Glow Coil again� Pilot gas will
flow for the entire 90-second trial� The system
will then lockout and retry after 5 minutes� Flame
rectification is sensed through the Flame Rod on the
Pilot/Igniter to ground via the Pilot Tube�
RADIANT FLAME BURNER TROUBLESHOOTING
Radiant Flame Burner
Pilot Tube
Burner Housing
Flame Jet
Pilot / Igniter
Fire Deck ovens may have one or more Radiant Burners located at the sides of the oven� In all Radiant Burner equipped ovens, it is
a primary heat source� Temperature may be controlled by adjusting the flame height at the Flame Height Control Knob (Valve) on the
front of the oven� Each Radiant Burner will have its own Flame Height Control Knob�
Flame Retention Spring
Содержание FIRE DECK 6045
Страница 41: ...PG 41 OF 44 M0011 09 APRIL 2019 Blank page ...