FD-9660/11260 GAS SPECIFICATIONS
FD-9660 AND FD-11260 GAS SPECIFICATIONS
Models
Underfloor IR Burner
Left Side Flame Burner
Right Side Flame Burner
W
ood F
ire Optional
W
ood F
ire Manda
tor
y
Optional Decora
tive Flame
Na
tural Gas (NG)
Propane (LP)
Propane (HLP)
Maximum
Gas
BTU/hr Input
Valve Outlet
Pressure
(W.C.)
SV
-1
SV
-2
SV
-3 / SV
-4
WS-FD-(9660 or 11260)-RFG-LR-IR
1
1
1
NG
350,000
3.5"
5"
5"
LP
9"
10"
10"
HLP
7"
7"
7"
WS-FD-(9660 or 11260)-RFG-(L or R)-IR
1
L or R -W
NG
225,000
3.5"
5"
LP
9"
10"
HLP
7"
7"
WS-FD-(9660 or 11260)-W-IR
1
X
NG
100,000
3.5"
LP
9"
HLP
7"
WS-FD-(9660 or 11260)-RFG-(L or R)-W
L or R
X
NG
125,000
5"
LP
10"
HLP
7"
WS-FD-(9660 or 11260)-RFG-(L or R)-CL 1
L or R
NG
225,000
3.5"
5"
LP
9"
10"
WS-FD-(9660 or 11260)-W
X
NA
NA
NA
*Optional Decorative Flame Burner
The Optional Decorative Flame Burner adds
15,000 BTU/hr to total rated input.
+DF
NG
+15,000
5"
LP
10"
HLP
10"
Optional FD-11260 Second IR Burner
(Adds 75,000 BTU/hr To total rated input)
2nd
NG
+75,000
3.5"
LP
9"
HLP
7"
This oven requires no modifications or adjustments for use at high altitudes.
GAS CODE LIMITATIONS
The installation of this appliance must conform with local codes, or in the absence of local codes, with the National
Fuel Gas Code, ANSI Z223.1 or The Natural Gas Installation Code CAN/CGA-B149.1 as applicable.
SV-1 is the gas control valve that operates the Underfloor Infrared (IR) Burner� The Manifold pressure is checked at the outlet port on
the SV-1 gas valve�
SV-2 (and SV-3 / SV-4 if equipped) are the gas control valve(s) that operate the interior Radiant Burner(s)� The Manifold pressure is
checked at the outlet port on the the individual gas valve�
The Burner Manifold pressures have been adjusted and tested at the factory� A variety of factors can influence these pressures,
so be sure to test the individual Burner Manifold pressures and adjust the valves as necessary to achieve the required pressures�
NOTE:
The gas valves are shipped in the
ON
position�
FACTORY SPECIFIED MAXIMUM HOURLY BTU INPUT RATES / BURNER MANIFOLD PRESSURES