woodstone-corp.com
OPERATION SEQUENCE - RFG
BURNER OPERATION SEQUENCES
RFG OVEN (NO INFRARED (IR) BURNER)
*
Note:
Ovens equipped with 2 Radiant Burners will have a second Valve, SV-3, which will be powered at the same time as the
SV-2 Valve described above� The operation sequence is identical to that of SV-2� However, the “chec” display will only
come on if both Burners fail to light�
Pilot lights
Power On
SV-2 powers Igniter and opens Pilot
Valve�*
Pilot does not light- SV-2 times out-
Touchpad style Controllers will flash “chec”�
If more than one RFG, Burner “chec” will
display only if all fail to light�*
SV-2 senses Pilot flame, turns Igniter off,
SV-2 opens, Burner lights, Dome Flame
Light comes on�
Burner remains on until oven Controller is
turned off�