Maintenance
6.4.2 Filling the release agent and checking the fill level
Prior to every commissioning, check the release agent level if possible.
Top off the release agent if necessary. We recommend using the
release agent from
WIWA
(order no. 0163333).
No.
Description
1
To fill the release
agent, slide the cover
for the filler opening to
the side and press the
release agent in by
means of the dosing
bottle.
2
The release agent
overflow is located
below the screw
connection of the air
motor with the material
pump.
3
The release agent
should be at the center
of the inspection glass
for optimal filling.
③
①
②
Fig. 23:
Filling and checking the release
agent
6.5 High pressure filter
6.5.1 Cleaning the filter element
The cleaning interval for the filter elements in the high pressure filters
is dependent on the type and cleanliness of the material. Clean the
filter elements at least once per week and with every material change.
50
Original Operation Manual
✓
, Status:
2021/07/23
1alpg_BA_en_bb-0550010