Operation
when work is interrupted and when decommissioning in order to
flush processing material out of the machine during an interruption
to the spray operation before it hardens.
Observe the pot life of the materials used, in particular when using
a multi-component material.
WARNING
The fine atomization of solvents can cause damage to health.
If necessary, interrupt the supply of atomizing air during the
flushing process.
WARNING
Heating cleaning agents can lead to an explosion. Serious personal
injuries and property damage may result.
Before flushing the machine, turn off the material fluid heater
(optional) and let it cool off completely.
You will need:
at least 5 l of cleaning agent, that is suitable for the material to be
processed and is recommended by the material manufacturer, in
an open container.
an additional electrically conductive collecting vessel for the clean-
ing agent that is flushed out.
These containers are not included in the scope of delivery.
1. Close and lock the spray gun.
2. Turn the working pressure on the compressed air regulator down
completely:
for the airless variant, this is the regulator for the air inlet pres-
sure.
for the AirCombi variant, this is the regulator for the air inlet
pressure and the regulator for the atomizing air.
Original Operation Manual
✓
, Status:
2021/07/23
1alpg_BA_en_bb-0550010
39
Содержание PHOENIX GX Series
Страница 1: ...1alpg_BA_en_bb 0550010 PHOENIX GX SERIES Operation Manual 1K Airless AirCombi Serial No...
Страница 4: ......
Страница 69: ...Technical Information Original Operation Manual Status 2021 07 23 1alpg_BA_en_bb 0550010 63...
Страница 70: ...Technical Information 64 Original Operation Manual Status 2021 07 23 1alpg_BA_en_bb 0550010...
Страница 71: ...Technical Information Original Operation Manual Status 2021 07 23 1alpg_BA_en_bb 0550010 65...