Eliminating operational faults
fault
possible cause
remedy
Pump running
smoothly, but the re-
quired spraying pres-
sure is not achieved.
Air pressure is too low
or too little air.
Increase the air
pressure on the
compressed air
regulator or check the
air line for the correct
cross-section.
Spray nozzle (new) is
too large.
Insert a smaller nozzle
or use a larger pump.
Spray nozzle worn (too
large).
Insert a new nozzle.
High pressure filter
blocked
Clean the filter element
(see section 6.5.1 on
page 50)