blueMatic EAV
Installation, Operating and
Maintenance Instructions
Figure 3.6.2-8: Installation blueMatic EAV with
Fingerprint IDENCOM BioKey
INSIDE and frame power supply
(sash side)
Notice:
The positioning of
frame power supply and
cable transition on the hinge
side is recommended, either
between lower / middle door
hinge or in each case approx.
10 cm above / below the
middle door hinge.
Do
not connect
external
voltage!
yellow / grey
= output signal swing door opener
(optional), only by motor housing
swing door
green / white
= input for external potential-free
contact (e.g. unlocking via
intercom / open button)
Notice!
max. 40 m extendable
(min. 0,8 mm
2
)
white + 12 V DC
brown 0 V
green
external opening signal
yellow
grey
pink
(unscript)
}
signal swing door
opener
230 V AC
Description
Art.-No.
Sash part cable transition
T-SET KÜ-T1 FT ZK-EAV
3,5 + Y 0,5 M including
Y-KABEL ZK FLÜGEL-EAV
5040508
Frame part cable transition
T-KÜ-T1 RT KABEL 0,6M
RNT, for frame power
supply
5040504
Motor housing EAV, for
retrofitting mechanical
locking system AV3,
standard
5009320
Frame power supply
T-NETZTEILRAHM. 12 V
DC 1,5 A (2A/2S)
5038587
Access control system
IDENCOM
Fingerprint IDENCOM
BioKey INSIDE Basic
without App
680 805
Fingerprint IDENCOM
BioKey INSIDE with App
692 815